Universal-Frequenzumrichter der E180-Serie
- Produktivität:
- 10, 000 Per Month
- Ort Von Zukunft:
- Zhejiang China (Festland)
- Versorgungsmaterial-Fähigkeit:
- 10, 000 Per Month
Basisinformation
Modell: CDI-E180G375/P400T4
Produktbeschreibung
Modell Nr .: CDI-E180G375 / P400T4 Ausgabetyp: Triple Switch Mode: PWM Steuerspannung der Stromversorgung: Mittelspannung Frequenzumrichter Art der DC-Leistung: Strom Variable-Frequenz-Laufwerk Marke: Delixi Nenneingangsstrom (a): 714 / 753 Adaptermotor (Kw): 375/400 Regelungsmethode: U / f-Steuerung, Vektorregelung SVC Startmoment: 0,5 Hz / 150% SVC Gewicht (kg): 500 Spezifikation: CE, CCC HS-Code: 8504409999 Anwendung: Hoch Leistung Transducer, dreiphasiger Transducer, allgemeiner Transducer, einphasiger Transducer, Hochfrequenzkonverter-Transducer, Wasserrohr Arbeitsprinzip: Vektorsteuerung Transducer Hauptstromkreis-Typ: Leistungsübertragungsstrecke: AC-DC-AC-Frequenzumrichter Funktion: Konstant Drehmoment Universalausführung Nennleistung (kVA): 467/494 Nennausgangsstrom (a): 710/750 Bremseinheit: Standard Eingebaute Überlastkapazität: 150% Nennstrom 60s; 180% Nennstrom 3s Abmessung (Mm): 390 * 600 * 267 Handelsmarke: DELIXI Ursprung: Zhejiang China (Festland) Produkt-Name: E180 Serie Univers al Integriere Frequenzumrichter \ n \ n * Liebe Freunde, du kannst mir deine Anforderungen mitteilen, ich werde Modelle für dich auswählen, wenn nötig & Zeitraum; \ n \ n \ n1 & Zeitraum; "Hohe Präzision", "hohe Leistung", "hohe Kosteneffektivität" & \ nZur Erfüllung der immer höheren Anforderungen an die industrielle Produktion von Frequenzumrichtern entwickelt Hangzhou Delixi einen neuen Frequenzumrichter der E-Serie, der auf die Anforderungen des Marktes ausgerichtet ist; Verglichen mit den alten Frequenzumrichtern, ist seine Präzision und Leistung neben seiner optimierten Struktur und Erscheinung & Periode wesentlich verbessert; Seine starke eingebaute Funktion kann die Notwendigkeiten der verschiedenen Industrien u. Periode besser erfüllen; \ n \ n2 & period; Hohe Regelgenauigkeit \ nDrehzahlregelung \ n1: 100 & lpar; SVC & rpar; 1: 1000 & lpar; VC & rpar; \ nGeschwindigkeitsstabilisierungsbereich \ n0 & Periode; 5 & # 981; SVC & rarr; 0 & Periode; 02 & Prozent; & lpar; VC & rpar; \ nDrehmomentsteuergenauigkeit \ n5 & percnt; & lpar; VC & rpar; \ n \ n3 & Zeitraum; Schnelle Drehmomentantwort \ nSVC: Drehmomentantwort <20ms \ nVC: Drehmomentantwort <5ms \ n \ n4 & Periode; Hohes Startdrehmoment \ n \ nSVC: 0 ÷ 5 Hz kann 150 & percnt; Startdrehmoment \ nVC: 0 HZ kann 180 & per; Drehmoment bei Nulldrehzahl \ n \ n5 & Periode; Verschiedene Vektorsteuerungen von Motoren sind verfügbar. \ N \ nDie Serie E180 kann asynchronen Motor und Synchronmotor & Periode ansteuern; \ n \ n6 & period; Verschiedene Menü-Anzeigemodi \ n \ n7 & Punkt; Funktion des eingebauten Timers \ n \ nEs verfügt über zwei eingebaute Timer, um die Eingangssignale zu sammeln und die Ausgabe der Zeitsignale & Periode zu realisieren; Eine solche Funktion kann einzeln oder in einer beliebigen Kombination und Periode verwendet werden. \ N \ n8 & Periode; Eingebautes virtuelles Zeitverzögerungsrelais \ n \ nEs verfügt über 5 integrierte virtuelle Zeitverzögerungsrelais für eine einfache Logikoperation für multifunktionale Ausgangsanschlüsse und digitale Eingangsklemmensignale & Periode; Das logische Ergebnis kann als äquivalent zur Eingangsanschlussfunktion betrachtet werden und kann auch von den multifunktionalen Ausgangsanschlüssen & ndash; Darüber hinaus können die Logikergebnisse mit Zeitverzögerungs- und Negationsoperationen & Periode durchgeführt werden. \ N \ n9 & rarr; Funktion des eingebauten Betriebsmoduls \ n \ nEin Quad-Betriebsmodul ist in & period eingebaut; Ein solches Modul kann eine einfache Addition, Subtraktion, Multiplikation, Division, Beurteilung der Größe und Integraloperationen & Periode durchführen; Jede Operation hat 4 Eingangsrichtungsadressen und eine Ausgangsadresse & Periode; Die Eingabeadresse ist der Funktionscode & Punkt; \ n \ n10 & Punkt; Funktion des schnellen Strombegrenzers \ n \ nIn dem Fall, dass der Strom den Stromschutzpunkt überschreitet, kann der schnelle Strombegrenzer den Strom innerhalb des Stromschutzpunktes halten, um häufiges Senden eines Überstromalarms durch den Frequenzumrichter zu verhindern und die Ausrüstung zu schützen. n \ n11 & zeitraum; Exzellente Fähigkeit der Antriebssteuerung \ n \ nDie maximale Antriebsleistung der 24-V-Ausgangsleistung des Frequenzumrichters der E-Serie, ausgestattet mit Strombegrenzungsalarmfunktion, kann 300mA betragen; \ n \ nDer Benutzer kann ihn verwenden, um Text zu versorgen, zu berühren Bildschirm, SPS und Relais statt Verbindung zu einem externen Schalter & Punkt; \ n
WARUM SIE UNS WÄHLEN & quest; \ n \ nQ1 & Zeitraum; Sind Sie Hersteller oder Handelsunternehmen & Quest; \ nA & Zeitraum; Wir sind der einzige Hersteller von elektrischen Produkten & Zeitraum; \ nWillkommen, unsere Fabrik jederzeit zu besuchen & Periode; \ n \ nQ 2 & Periode; Was ist der Zahlungsausdruck? \ nA & Zeitraum; Wir akzeptieren T & L; T, L & C; WESTERN UNION \ n \ nQ 3 & Periode; Was ist die lieferzeit & quest; \ nA & Zeitraum; Normales Modell 1-3days, weil wir Fähigkeit haben, den Vorrat u. Periode zu tun; \ nFür großen Auftrag dauert es ungefähr 15-20days & period; \ n \ nQ 4 u. Periode; Was ist der Standard von Paket & Quest? \ nA & Zeitraum; Standard-Paket oder spezielles Paket nach Kundenwunsch exportieren \ n & Zeitraum; \ nQ 5 & Zeitraum; welche art von produkt qualität ihre fabrik bieten & quest; \ nA & Zeitraum; Wir sind Top 3 aus dem chinesischen Markt & Zeitraum; Wir bieten Top-Qualität, um Kunden zu helfen, mehr Markt und Periode zu bekommen; \ n \ nQ 6 & Periode; Akzeptieren Sie OEM-Geschäft & Quest; \ nA & Zeitraum; Wir tun OEM & Zeitraum; \ nQ 7 & Zeitraum; Welche Markt verkaufen Sie bereits & quest; \ nA & Zeitraum; Wir versenden bereits nach Mittlerer Osten, Asien, Russland, Afria etc & Zeitraum; \ n \ nQ8 & Zeitraum; Welche Art von Zertifikat haben Sie? \ nA & Zeitraum; Wir haben ISO9001, CE, CCC, etc & Zeitraum;
Item | Specification | |
Control | Control Mode | V/F control |
Open-loop Vector Control (SVC) | ||
Vector Control (VC) (Not applicable to E100/E102/EM60 series) | ||
Frequency Precision | Digital: 0.02% | |
Analog: 0.1% | ||
V/F Curve | Linear, square root, any V/F | |
Overload Capacity | G-type: 150% rated current for 60s; 180% rated current for 3s | |
P-type: 120% rated current for 60s; 150% rated current for 3s | ||
Start Torque | G-type: 0.5Hz/150% (SVC); 0Hz/180% (VC) | |
Speed Adjustment Range | 1:100 (SVC) 1:1000 (VC) | |
0.5% (SVC) 0.02% (VC) | ||
Torque Precision | 5% (VC) | |
Torque Compensation | Manual torque compensation (0.10%-30.0%); Automatic torque compensation | |
Operating Mode | Key-board, terminal, RS485 communication | |
Basic Type Function | Frequency Source | 14 main sources, 14 auxiliary sources. |
Easy switch between different modes. | ||
Diversified input modes for every source: keyboard potentiometer, external analog, | ||
digital setting, pulse frequency, multi-speed, simple PLC, communication, computing | ||
results, etc. | ||
Torque Source | 14 torque sources, including digital setting, external analog, pulse setting, | |
multi-order, communication, computing results, etc. | ||
Acceleration and Deceleration Time | 4 groups of lines (can be switched through the option terminals); S Curve 1, S Curve 2 | |
Emergency Stop | Interrupt the output instantaneously | |
Multi-speed | 16-shift speeds at most; can be switched by different combination of order terminals | |
Simple PLC | Continuous operation of 16-shift speeds; the acceleration/deceleration time, operating | |
time and frequency source for every shift can be set separately | ||
Inching Control | Inching frequency and inching acceleration/deceleration time can be set separately; | |
Inching can be prioritized in process. | ||
Rotating-speed Track | Track the start speed and operating speed of the inverter's load | |
Length and Distance Control | Length and distance control through pulse inputs | |
Counting | Counting through pulse inputs | |
Swing Frequency | For winding machines in the textile industry | |
Internal PID | Closed-loop process control system is available | |
AV R | Ensure constant output in case of fluctuating grid voltage | |
DC Brake | Quick and stable parking is available | |
Slip Compensation | Compensate the slip deviation due to increased load | |
Hopping Frequency | Prevent resonance with the load | |
Droop Function | Balance the load rate of different motors which drive the same load | |
Timing | Automatic stop at a given time |
Item | Specification | |
Enhanced Function | Internal Virtual Time Delay Relay | Simple logic programming for the multi-functional output terminals and the digital input terminals. |
The logic results can be equivalent to the digital input terminal function, and can be output through | ||
the multi-functional output terminals | ||
Internal Timer | Two internal timers to collect timing input signals and to output timing signals. | |
The two timers can be used separately or together | ||
Internal Math | One internal 4-way math operation module for elementary arithmetic operations, numerical | |
Operation Module | magnitude judgment and integral operation | |
Communication | E100 | The control panel has a RS485 communication interface which supports standard MODBUS-RTU |
protocol | ||
E102/E180/EM60 | The control panel does not have a RS485 communication interface, and an external 485 | |
communication expansion card shall be connected. Support standard MODBUS-RTU protocol. The | ||
E180-series also support standard PROFIBUS-DP protocol (through an external E180-DP expansion | ||
card). | ||
Coder | E100 | The coder can be connected directly through the DI5 and DI6 terminals on the control panel, and |
simple closed-loop control is available through PID control. Such connection is used in undemanding | ||
situations. | ||
EM60 | The control panel does not have any interface for the coder, and a one-way high-speed pulser can be | |
extended (through DI6). | ||
E102 | The control panel only has one coder interface (DI6). | |
E180 | The control panel does not have any coder interface, and an external coder expansion card is | |
necessary. The inverter supports ABZ incremental coder, UVW incremental coder and resolver. Such | ||
connection enables high-performance VC, and can be used in situations with demanding control | ||
precision requirements. | ||
Motor | E100/E102 | Only for asynchronous motors |
E180 | For asynchronous motors and synchronous motors | |
Display | Operation Information | Given frequency, output frequency, output voltage, busbar voltage, input signal, feedback value, |
module temperature, and synchronous speed of the motor. At most 32 parameters can be displayed in | ||
cycle through the ">>" key. | ||
Fault Information | In the fault protection mode, three pieces of history fault information can be saved. Every piece | |
includes the frequency, current, busbar voltage and I/O terminal status when the fault takes place. | ||
Protection | Inverter Protection | Over-current, over-voltage, module fault protection, under-voltage, overheat, overload, external fault |
protection, EEPROM fault protection, ground protection, and default phase | ||
Inverter Alarm | Locked-rotor protection, overload alarm | |
Instantaneous Power Down | Less than 15 ms: continuous operation | |
More than 15ms: automatic restart | ||
Environment | Ambient Temperature | -10ºC~ 40ºC |
Storage Temperature | -10ºC~ 40ºC | |
Ambient Humidity | Max. 90% RH (No condensation) | |
Altitude/Vibration | Below 1000m; below 0.6g | |
Working Place | No corrosive gas, inflammable gas, oil mist or dust | |
Cooling | Force-air cooling |
Operation | Operation Control Mode | Keyboard/External Terminals/RS485 Communication |
Start Mode | Current Limit/ Voltage/ Heavy-load | |
Start/Stop Time | Digital Settings | |
Start Delay | Digital Settings | |
Emergency Stop | Interrupt the output of the soft starter | |
Current Limit | Start current below this value in the current limit and heavy-load modes | |
Start Voltage | Start voltage can be set digitally in the voltage mode | |
Light-load Control | Belt tripping can be detected | |
Restart | Restart automatically after stopped due to fault | |
Fault Output | Contact output: | |
Multi-functional Relay Output | Start delay, start, operation, stop, complete stop, restart | |
Analog Output | 0-20mA/ 4-20mA, optional | |
Protection | Soft Starter Protection | Over-current, overload, overheat, three-phase imbalance, default phase, light-load, external fault |
Soft Starter Alarming | Emergency stop, light-load, restart | |
Display | Keyboard | |
Operation Information | Ready, start delay, start, operation, stop, fault alarm | |
Parameter Protection | Protect the parameters from being altered | |
Working Conditions | Type | AC-53b 660V Rated Impact-withstanding Voltage: 4kV |
Rated Insulation Voltage | CDRA011T4~CDRA055T4: IP20 | |
Degree of Protection | CDRA075T4~CDRA600T4: IP00 | |
Environment | Ambient Temperature | -10ºC~ 40ºC |
Storage Temperature | -20ºC~ 65ºC | |
Ambient Humidity | 90% RH at most (No condensation) | |
Altitude/Vibration | <1000m;<5.9m/s2 (=0.6g) | |
Working Place | No corrosive gas, inflammable gas, oil mist, or dust | |
Cooling | Natural Cooling |
Model | Brake Unit | Brake Resistance | Power (W) |
CDI-EM60G0R4S2B | Internal, Max. Current of 8A | 400 | 80 |
CDI-EM60G0R75S2B | Internal, Max. Current of 8A | 200 | 160 |
CDI-EM60G1R1S2B | Internal, Max. Current of 8A | 160 | 200 |
CDI-EM60G1R5S2B | Internal, Max. Current of 15A | 120 | 250 |
CDI-EM60G2R2S2B | Internal, Max. Current of 15A | 80 | 400 |
Model | Brake Unit | Brake Resistance | Brake Resistor Power (W) |
S2 (Single-phase 220V) | |||
CDI-E100G0R4S2B | Internal, Max. Current of 8A | 400 | 80 |
CDI-E100G0R75S2B | Internal, Max. Current of 8A | 200 | 160 |
CDI-E100G1R5S2B | Internal, Max. Current of 15A | 120 | 250 |
CDI-E100G2R2S2B | Internal, Max. Current of 15A | 80 | 400 |
T2 (Three-phase 220V) | |||
CDI-E100G0R4T2B | Internal, Max. Current of 8A | 400 | 80 |
CDI-E100G0R75T2B | Internal, Max. Current of 8A | 200 | 160 |
CDI-E100G1R5T2B | Internal, Max. Current of 15A | 120 | 250 |
CDI-E100G2R2T2B | Internal, Max. Current of 25A | 80 | 400 |
T4 (Three-phase 380V) | |||
CDI-E100G0R75T4B | Internal, Max. Current of 8A | 600 | 160 |
CDI-E100G1R5T2B | Internal, Max. Current of 8A | 400 | 250 |
CDI-E100G2R2T4B | Internal, Max. Current of 15A | 250 | 400 |
CDI-E100G3R7T4B | Internal, Max. Current of 15A | 150 | 600 |
CDI-E100G5R5/P7R5T4B | Internal, Max. Current of 40A | 100 | 1000 |
CDI-E100G7R5/P0R11T4B | Internal, Max. Current of 40A | 75 | 1200 |
CDI-E100G011/P015T4BL | Internal, Max. Current of 50A | 50 | 2000 |
CDI-E100G015/P018.5T4BL | Internal, Max. Current of 75A | 40 | 2500 |
CDI-E100G0185/P022T4 | Internal, Max. Current of 50A Connect to External CDI-BR-50 | 30 | 4000 |
CDI-E100G022T4 | Internal, Max. Current of 50A Connect to External CDI-BR-50 | 30 | 4000 |
Model | Brake Unit | Brake Resistance | Brake Resistor Power (W) |
T2 (Three-phase 220V) | |||
CDI-E180G0R4T2B | Internal, Max. Current of 10A | 350 | 160 |
CDI-E180G0R75T2B | Internal, Max. Current of 10A | 300 | 160 |
CDI-E180G1R5T2B | Internal, Max. Current of 25A | 100 | 250 |
CDI-E180G2R2T2B | Internal, Max. Current of 25A | 75 | 400 |
CDI-E180G3R7T2B | Internal, Max. Current of 40A | 45 | 600 |
CDI-E180G5R5T2B | Internal, Max. Current of 50A | 30 | 1000 |
CDI-E180G7R5T2BL | Internal, Max. Current of 75A | 20 | 1200 |
CDI-E180G011T2 | Internal, Max. Current of 50A (Connect to External CDI-BR-50) | 16 | 2000 |
CDI-E180G015T2 | CDI-BR-100 | 12 | 2500 |
CDI-E180G018.5T2 | CDI-BR-100 | 20/2 | 4000 |
CDI-E180G022T2 | CDI-BR-100 | 16/2 | 4000 |
CDI-E180G030T2 | Internal, Max. Current of 75A (Connect to External CDI-BR-50) | 13.6/2 | 6000 |
T4 (Three-phase 380V) | |||
CDI-E180G0R75T4B | Internal, Max. Current of 10A | 600 | 160 |
CDI-E180G1R5T4B | Internal, Max. Current of 10A | 400 | 250 |
CDI-E180G2R2T4B | Internal, Max. Current of 15A | 250 | 400 |
CDI-E180G3R7/P5R5T4B | Internal, Max. Current of 25A | 150 | 600 |
CDI-E180G5R5MT4B | Internal, Max. Current of 40A | 100 | 1000 |
CDI-E180G5R5/P7R5T4B | Internal, Max. Current of 40A | 100 | 1000 |
CDI-E180G7R5/P011T4B | Internal, Max. Current of 40A | 75 | 1200 |
CDI-E180G011MT4B | Internal, Max. Current of 50A | 50 | 2000 |
CDI-E180G0011/P015T4BL | Internal, Max. Current of 50A | 50 | 2000 |
CDI-E180G015/P018.5T4BL | Internal, Max. Current of 75A | 40 | 2500 |
CDI-E180G018.5/P022T4 | Internal, Max. Current of 50A (Connect to External CDI-BR-50) | 30 | 4000 |
CDI-E180G022/P030T4 | Internal, Max. Current of 75A (Connect to External CDI-BR-50) | 30 | 4000 |
CDI-E180G030/P037T4 | Internal, Max. Current of 50A (Connect to External CDI-BR-50) | 20 | 6000 |
CDI-E180G037/P045T4 | CDI-BR-100 | 16 | 9000 |
CDI-E180G045/P055T4 | CDI-BR-100 | 13.6 | 9000 |
CDI-E180G055/P075T4 | CDI-BR-100 | 20/2 | 12000 |
CDI-E180G075/P093T4 | CDI-BR-200 | 13.6/2 | 18000 |
CDI-E180G093/P110T4 | CDI-BR-200 | 20/3 | 18000 |
CDI-E180G110/P132T4 | CDI-BR-200 | 20/3 | 24000 |
CDI-E180G132/P160T4 | CDI-BR-200 | 20/4 | 36000 |
CDI-E180G160/P185T4 | CDI-BR-400 | 13.6/4 | 45000 |
CDI-E180G185/P200T4 | CDI-BR-400 | 13.6/5 | 45000 |
CDI-E180G200/P220T4L | CDI-BR-400 | 13.6/5 | 54000 |
CDI-E180G250/P280T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G280/P315T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G315/P355T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G355/P375T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G375T4L | CDI-BR-400 | 13.6/6 | 63000 |
CDI-E180G400T4L | CDI-BR-600 | 13.6/7 | 63000 |
CDI-E180G400T4L | CDI-BR-600 | 13.6/7 | 72000 |
CDI-E180G500T4L | CDI-BR-600 | 13.6/8 | 72000 |
CDI-E180G500T4L | CDI-BR-600 | 13.6/8 | 81000 |
CDI-E180G630T4L | CDI-BR-600 | 13.6/9 | 81000 |
CDI-E180G200T4L | CDI-BR-600 | 13.6/9 | 90000 |
CDI-E180P250T4L | 2 CDI-BR-400 | 13.6/10 | 18000 |
Produktgruppe : Frequenzumwandler
Premium Related Products
andere Produkte
heiße Produkte
Neuer Industrie-Feder-Druckmessgerät-DrucktransmitterTragbarer IGBT-DC-MMA-Schweißer (ZX7-200S)DC-Argon-WIG-SchweißmaschineDelixi Digital 200A MIG Schweißgerät (NBC-200ID)Delixi 2014 Neueste Digital IGBT 40A Plasma Schneidemaschine (LGLK-40ID)Delixi 2014 Neueste Digital DC Arc SchweißerDelixi E180 Serie 0.75kw-630kw Vektor Frequenzumrichter für MotorDelixi Serie Digital Pulse WIG Schweißen Maschine (WSM-200ID)CE AC / DC Schweißer mit Rädern 250/300/400 / 500amp Modell B / Industriemaschine / billig tragbare Schweißmaschine Preis / SchweißenCE Stahl Material portable mosfet mma / tig / cut Puls CT-416 / industrielle Maschine / tragbare Schneidemaschine PreisCE zugelassen ac dc wsme 250 315 tig SchweißgerätWIG DC Inverter SchweißgerätCE GS genehmigt Co2 Gas Schweißer MIG SchweißmaschineItalien-Technologie MIG-Schweißmaschine einphasig (1 ph)CE genehmigt kleinen Inverter IGBT DC Elektrodenschweißgerät tragbare SchweißmaschineHeavy Duty Drei-Phasen-IGBT-Modul 500 Ampere MMA Inverter Lichtbogenschweißmaschine